Place of Origin : Sichuan, China (Mainland)

Brand Name : Vacorda

Model Number : LZ

Supply Ability : 300 Piece/Pieces per Month

Packaging Details : Standard wooden box

MOQ : 1 Piece/Pieces

Price : Negotiable

Certification : CE/TUV/ISO9001/SGS

Product Name : Metal Pipe Float Flowmeter

Diameter : DN15~DN200

Accuracy class : Standard:1.5; Special: 1.0

Application : level measuring for gas, liquid and steam

Output : 4-20mA

Material : 304,316,316L,321,304 lined with PTFE,Hastelloy,Ti

Power supply : Standard: 24VDC; Battery type:3.6V lithium battery(3 years lifetime)

Connection form : Stabndard:DIN2501 standard flange,special: customized

Wiring connection : M20X1.5 female thread; 1/2NPT female thread for Exd explosion

Medium temperature : Standard:-40~+100℃,PTFE:-50~100℃,High temperature type:110~450℃

Port : Shanghai/Shenzhen

Contact Now

Smart Digital Metal Tube Rotameter Float Types For Measure Flow Of Gas

Product Description

Metal pipe float flowmeter consists of measuring pipe, float, indicator and process connection components with the characteristics of small size, wide measuring range, easy installation. In the industry area, it is widely used to measure flow of gas, liquid, and steam, especially suitable for mediums with low current velocity and low flow rate.

Smart Digital Metal Tube Rotameter Float Types For Measure Flow Of Gas

Product Parameters

Measuring range

Water:1~200000L/H(20°C)

Air: 0.03~6000m3/h (20°C, 0.1013MPa)

Measuring range proportion

Standard: 10:1

Accuracy class

Standard:1.5; Special: 1.0

Pressure class

Standard:DN15~DN504.0MPa; DN80~DN2001.6MPa

High pressure:DN15~DN5032MPa;DN80~DN20016MPa

Pressure loss

7kPa~70kPa

Medium temperature

Standard:-40°C~+100°C; PTFE:-50°C~+100°C

High pressure:110°C~+450°C

Medium viscosity

DN15:η<5mPa.s(F15.1~F15.3), η<30mPa.s(F15.4~F15.8)

DN25:η<250mPa.s; DN50~DN200:η<300mPa.s

Environment temperature

Remote type: -40°C~+85°C

On-the spot needle indicator: -40°C~+100°C

Connection type

Standard: DIN2501 standard flange; special: customize

Wiring connection

M20×1.5 female thread (1/2NPT female thread for Exd explosion-proof)

Power supply

Standard: 24VDC two-line 4~20mA(12VDC~32VDC)

Warning type:24VDC four-line 4~20mA(18VDC~18VDC)

AC type:85~265VAC 50HZ

Battery type:3.6V 7.5AH lithium battery(3 years lifetime)

Loading resistance feature

Two-line: max loading resistance=50×(voltage-12)Ω=600Ω 24V

Multi-line: max loading resistance 500Ω

Warning signal output

Reed pipe warning switch output,upper limit and lower limit flow warning

(contact capacity 1A 30VDC)

electric relay output(contact capacity 1A 30VDC, 0.25A 250VAC,0.5A 125VAC)

pulse output

Min space 50ms (max loading 100mA 30VDC, internal resistance 100Ω)

LCD display

Instantaneous flow display scope:0~50000

Total flow display scope: 0~99999999

Protection grade

IP65

Explosion-proof grade

Exia II CT5Ga Exd II BT6Gb

Detailed Images
Smart Digital Metal Tube Rotameter Float Types For Measure Flow Of GasSmart Digital Metal Tube Rotameter Float Types For Measure Flow Of Gas
Production and Processing
Application
The development of flow measurement can be traced back to ancient water conservancy projects and urban water supply systems. In ancient Roman Caesar times, orifice plates were used to measure the drinking water volume of residents. The ancient Egypt used the weir method to measure the flow of the Nile River around 1000 BC. my country's famous Dujiangyan water conservancy project uses the water level of Aquarius to observe the amount of water and so on. In the 17th century, Torri laid the theoretical foundation for differential pressure flow meters, which was a milestone in flow measurement. Since then, prototypes of many types of meters for flow measurement in the 18th and 19th centuries have begun to form, such as weirs, tracers, pitot tubes, venturis, volumes, turbines, and target flow meters. In the 20th century, the rapid growth of the demand for flow measurement in the process industry, energy measurement, and urban utilities only promoted the rapid development of instruments. The rapid development of microelectronics technology and computer technology greatly promoted the replacement of instruments. . So far, it is said that hundreds of flowmeters have been put on the market, and many difficult problems in field use are expected to be solved.

Product Tags:

rotameter type flow meter

      

metal tube variable area flow meter

      
Quality Smart Digital Metal Tube Rotameter Float Types For Measure Flow Of Gas wholesale

Smart Digital Metal Tube Rotameter Float Types For Measure Flow Of Gas Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Sichuan Vacorda Instruments Manufacturing Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)